Korean Journal of Otorhinolaryngology-Head and Neck Surgery 1980;23(3): 342-6.
Treatment of Tracheal Stenosis Using Silicone T-tube
Jong Jin Chung, MD (Director : Prof. Chong Won Lee, MD)
Department of Otolaryngology, Chonnam National University, Medical School, Korea
氣管狹窄症에 對한 Silicone T-tube의 治療經驗
丁鍾珍 (指導 : 李鍾元 敎授)
全南大學校 醫科大學 耳鼻咽喉科學敎室
ABSTRACT

The silicone tracheal T-tube was designed to maintain an adequate tracheal airway as well as to provide support in the stenotic reconsituted or reconstructed trachea. This report is our experiences with using silicone T-tubes which were successfully used to two cases with extensive laryngotracheal trauma and one case with decannulation difficulty for 9 months. Author strongly believe that silicone T-tube is excellent device out of consideration for our experienced cases, though many techniques have been applied for the treatments of tracheal problems.