					Korean Journal of Otorhinolaryngology-Head and Neck Surgery 1988;31(3): 439-42. 				 | 
	 
 
	
	
	
	
		| Clinical Study on Effect of Foley Catheter in Bleeding Control of Caldwell-Luc's Operation and Epistaxis | 
	 
	
		| Chin Choi, MD, Seung Hun Chang, MD, Young Min Park, MD,  and Sun Chul Lee, MD | 
	 
	
		| Department of Otolaryngology, Hangang Sacred Heart Hospital, College of Medicine, Hallym University, Korea | 
	 
			
			| 부비동 및 비강의 지혈에 있어 Foley Catheter의 효과에 대한 통계적 고찰 | 
		 
		
			| 최 진 · 장승훈 · 박영민 · 이선철 | 
		 
		
			| 한림대학교 의과대학 한강성심병원 이비인후과학교실 | 
		 
	
		
		| 
				 | 
	 
	
		| 
				 | 
	 
		 |  		
		
		| ABSTRACT | 
	 
	
		| 
		 The authors used a Foley catheter for the control of the bleeding from the maxillary antrum after Caldwell-Luc's operation. The 956 patients with chronic paranasal sinusitis(1,741 cases of Caldwell-Luc's operation) were selected during 10 years from Jan. 1976 to Dec. 1985. There were excellent bleeding control effect in 1,536 cases(88.2%), good bleeding control effect in 134 cases(7.7%) and little effect in 37 cases(2.1%). We experienced excellent bleeding control effect in most of cases and patients felt little pain during the removal of a Foley catheter. And We experienced good bleeding control effect in posterior nasal bleeding for the 112 patients admitted during the same period. 
		 | 
	 
		
							 
	 | 
 
 
 
 | 
	
 |