Korean Journal of Otorhinolaryngology-Head and Neck Surgery 1994;37(6): 1160-7.
A Study of Middle Ear Pressure Change during General Anesthesia with Nitrous Oxide
Mi Ra Kim, MD, Jeong Seop Lee, MD, Han Kook Lee, MD, Cheong Sam Lee, MD, and Tai Hyun Yu, MD
Department of Otolaryngology, Kosin Medical College, Pusan, Korea
아산화질소마취시 중이강의 압력변화에 관한 연구
김미라 · 이정섭 · 이한국 · 이정삼 · 유태현
고신대학교 의과대학 이비인후과학교실
ABSTRACT

The nitrous oxide anesthesia is known to induce middle ear pressure variations. The middle ear pressure begin to rise immediately after the inhalation of nitrous oxide. The mechanism of this increase is known to be due to the difference in blood solubility between nitrous oxide and nitrogen. Repeated cycle of gradual rise and sudden fall of the pressure occur during anesthesia due to the diffusion of nitrous oxide and passive venting of the eustachian tube. After cessation of nitrous oxide administration, the gas diffuses out of middle ear faster than nitrogen diffuses in. Consequently, the total pressure falls producing the negative pressure within the middle ear. The present study was undertaken to investigate if such changes in middle ear pressure also occur during anesthesia with low concentration of nitrous oxide. In 30 patients without ear diseases, the middle ear pressure was measured with an impedance audiometer(Danplex C 186, Danamedica, Copenhagen, Denmark) during anesthesia with 50% nitrous oxide. We observed a significant increase in the middle ear pressure during the administration of nitrous oxide and a significant decrease after nitrous oxide was discontinued. These results indicate that nitrous oxide inhalation induced a significant change in the middle ear pressure even in a low concentration, thus we advice that the administration of nitrous oxide be ceased at least fifteen minutes before the middle ear cleft is closed by grafting a tympanic membrane defect or replacing a tympanomeatal flap. 

Keywords: Nitrous oxideMiddle ear pressureImpedance audiometer.
Editorial Office
Korean Society of Otorhinolaryngology-Head and Neck Surgery
103-307 67 Seobinggo-ro, Yongsan-gu, Seoul 04385, Korea
TEL: +82-2-3487-6602    FAX: +82-2-3487-6603   E-mail: kjorl@korl.or.kr
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © Korean Society of Otorhinolaryngology-Head and Neck Surgery.                 Developed in M2PI
Close layer
prev next